Sensus Meijet Single Jet Bulk Water Meter


Sensus Meijet Single Jet Bulk Water Meter

Download Data Sheet

The Meijet cold water meter provides exceptional low flow accuracy. Its unique design enables the passage of water born particles that would otherwise block or damage other flowmeters.

  • Single Jet Turbine design
  • Exceptional low flow characteristics
  • Tolerant of particulate matter
  • Very low pressure drop
  • Sizes 50 to 100mm 
      

INV/MJT Range
Meter Size
 
mm
50
65
80
100
Nominal Flow
Qn
m3/h
15
20
30
50
Maximum Flow
Qmax
m3/h
40
60
90
120
Transitional Flow
Qt
m3/h
0.1
0.14
0.18
0.30
Minimum Flow
Qmin
m3/h
0.07
0.1
0.1
0.2
Starting Flow
 
m3/h
0.03
0.04
0.04
0.07
Max Working Pressure
Bar
16
16
Pulse Resolution
p/m3
0.01 + 1m3
Max Working Temperature
°C
50
Metrological Class
 
Class C