Sensus 620 - High Accuracy Cold Water Meter

Sensus 620 - High Accuracy Cold Water Meter

Download Data Sheet Download Short Form Download O and M Manual

The 620 rotary piston flowmeter is in operation with water utilities throughout the UK and is one of the few meters to be approved for use within UK water systems. With an installed base in-excess of 4 million the 620 meter is a proven world leader.

  • EEC/ISO Approved Class B, C & D
  • Weights & Measures and WRAS Certified
  • Rotary Piston Technology
  • Easy Read – Hermetically sealed registers
  • Pre-equipped for retrofitable pulse fitting
  • In operation with UK water companies
  • Manifold (Concentric) version for meter boxes
  • Range of remote meter reading options
  • Exceptionally low flow characteristics
  • Sizes 15mm to 40mm 

  More information on our 620 HRI pulse unit...

 

INV/620 Range
Meter Size
 
mm
15
15
20
25
30
40
Nominal Flow Qn
 
m3/h
 
1
 
1.5
 
2.5
 
3.5
 
6
 
10
 
Maximum Flow Qmax
 
m3/h
 
2
 
3
 
5
 
7
 
12
 
20
 
TransitionalFlow Qt
 
l/h
 
15
 
22.5
37.5
52.5
90
 
150
 
Minimum Flow Qmin
 
l/h
 
10
 
15
 
25
 
35
 
60
 
100
 
Starting Flow
l/h
<1
<1
2
7
7
8
Max Working Pressure
Bar
 
16
 
16
 
Totaliser Range
M3
 
99 999
 
Minimum Reading
Litres
 
0.05
 
0.2
 
Max Working Temperature
°C
 
30
 
Max Pressure Loss at Qmax
Bar
 
<1
 